  3. ENDRESS HAUSER 5H1B04-15J5/0

ENDRESS HAUSER 5H1B04-15J5-0 Promag Flowmeter 5H1B04-15J5/0 5H1B22-2H41/0

5h1b22-2h41 Endress Hauser 5h1b04-15j5/0 Promag H 100 Electromagnetic Flowmeter 5h1b22-2h41/0

( Brand: Endress Hauser ), ( Manufacturer Part Number: 5H1B04-15J5/0 ), ( Flow Meter Type: Electromagnetic Flow Meter ), ( Port Diameter: 5/32 In ), ( Maximum Flow Rate: 7.57 L/min ), ( Country Of Origin: France )

Review ENDRESS HAUSER 5h1b04-15j5/0 Promag100 Electromagnetic Flowmeter 5h1b22-2h41/0

The **Endress Hauser Promag 5H1B04-15J5/0** and **5H1B22-2H41/0** represent a cutting-edge, high-performance magnetic flowmeter series designed for precise, reliable, and maintenance-free measurement of conductive liquids in industrial and process applications. Part of the **Promag W** series, these instruments are engineered to deliver exceptional accuracy, durability, and versatility, making them ideal for demanding environments where dependable flow monitoring is critical. The **5H1B04-15J5/0** features a **50 mm (2-inch) pipe size** with a **stainless steel (1.4571/316Ti) liner and electrodes**, ensuring compatibility with aggressive media, high temperatures, and corrosive conditions. Its **dual-channel measurement principle** enhances signal integrity, reducing the risk of false readings caused by process disturbances, while the **integrated electronics** provide robust data processing and communication capabilities. The **5H1B22-2H41/0**, on the other hand, incorporates a **2-inch (50 mm) pipe size with a PTFE (polytetrafluoroethylene) liner**, offering superior chemical resistance and low-friction properties, making it particularly suited for applications involving highly corrosive or abrasive fluids, such as acids, alkalis, or slurries. Both models leverage **Endress Hauser s patented Promag W technology**, which combines **electromagnetic induction with advanced signal processing** to achieve a measurement accuracy of ** 0.5% of the actual flow rate** (repeatability as tight as ** 0.1%**), even under turbulent or pulsating flow conditions.

These flowmeters are equipped with a **hybrid sensor design**, featuring **ceramic ferrite cores** for enhanced signal stability and **stainless steel or PTFE liners** to prevent wear and contamination. The **electrode configuration** is optimized for minimal fouling and easy cleaning, while the **flange-mounted design** ensures quick installation and removal without disrupting the pipeline. The **integrated display and communication interface** supports multiple protocols, including **HART, PROFIBUS PA, FOUNDATION Fieldbus, and Modbus RTU**, enabling seamless integration with **SCADA systems, PLCs, or remote monitoring platforms**. Additionally, the **Promag W** series includes **automatic temperature compensation**, **zero suppression**, and **turbulence compensation**, ensuring consistent performance across varying operating conditions. Both the **5H1B04-15J5/0** and **5H1B22-2H41/0** are **ATEX-certified (II 2G/Ex ia IIC T4)** and **IECEx-certified**, making them suitable for use in **hazardous areas**, including **Zone 0, 1, and 2** environments. Their **wide temperature range** (from **-40 C to 120 C** for the stainless steel version and **-40 C to 80 C for the PTFE-lined model**) and **pressure ratings** (up to **16 bar for the 2-inch size**) further expand their applicability in diverse industrial sectors, such as **water and wastewater treatment, chemical processing, food and beverage, pharmaceuticals, and oil and gas**. With **low-pressure drop characteristics** and **no moving parts**, these flowmeters minimize energy consumption and operational downtime while delivering **long-term reliability** with minimal maintenance requirements. Endress Hauser s **Promag W** series exemplifies the fusion of **innovative engineering, robust construction, and intelligent measurement technology**, providing users with a **future-proof solution** for precise flow monitoring in the most challenging applications.

### **Pros and Cons of buying a Endress Hauser Promag 5H1B04-15J5/0 (5H1B22-2H41/0) Magnetic Flowmeter**

#### **Pros**

1. **High Accuracy and Reliability**

The Promag series is known for its precise measurement capabilities, with an accuracy of 0.2% of the measured value over a wide range of flow rates. This makes it suitable for applications requiring strict process control, such as chemical, pharmaceutical, and food & beverage industries.

2. **Wide Range of Applications**

The flowmeter is designed for clean and dirty liquids, slurries, and aggressive media, including corrosive chemicals, acids, and bases. The robust construction ensures durability in harsh environments.

3. **Maintenance-Free Operation**

Since it is a magnetic flowmeter, it has no moving parts inside the sensor, reducing wear and tear. This eliminates the need for regular recalibration or mechanical maintenance, lowering long-term operational costs.

4. **Versatile Installation Options**

The flowmeter can be installed in various orientations (horizontal, vertical, or even upside-down in some cases) and is compatible with different pipe sizes (from small DN15 to large DN3000). This flexibility makes it adaptable to different pipeline configurations.

5. **Corrosion and Abrasion Resistance**

The sensor body is typically made of high-quality materials such as stainless steel (e.g., 1.4404/316Ti) or other alloys, ensuring resistance to corrosion and abrasion. This extends the lifespan of the device in demanding environments.

6. **Advanced Digital Communication**

The flowmeter supports multiple communication protocols (e.g., HART, Profibus, Foundation Fieldbus, Modbus), allowing seamless integration with PLCs, SCADA systems, and other industrial control networks. This enhances process automation and monitoring.

7. **Low Pressure Drop**

The sensor has a smooth, streamlined design, resulting in minimal pressure loss across the pipeline. This is beneficial for energy-efficient operations, especially in large-scale systems.

8. **Temperature and Pressure Compatibility**

The flowmeter can operate across a wide temperature range (typically -20 C to 200 C, depending on the model) and handle high pressures (up to 400 bar in some configurations). This makes it suitable for high-temperature and high-pressure applications.

9. **Easy Calibration and Configuration**

The Promag series often includes user-friendly calibration tools and software, allowing for quick setup and verification of performance. This reduces downtime during commissioning or maintenance.

10. **Compliance with Industry Standards**

The flowmeter meets international standards such as IEC 60068 (environmental testing), ATEX (explosion-proof certification for hazardous areas), and FDA/3A compliance for food and pharmaceutical applications, ensuring reliability in regulated industries.

---

#### **Cons**

1. **High Initial Cost**

The Promag 5H1B series is a premium product, and the upfront purchase price can be significantly higher than basic mechanical or ultrasonic flowmeters. This may be a barrier for small businesses or budget-constrained projects.

2. **Limited to Conductive Liquids**

Magnetic flowmeters rely on the conductivity of the fluid to generate a measurable signal. They are **not suitable** for gases, steam, or non-conductive liquids (e.g., pure water, oils, or organic solvents). This limits their applicability in certain industries.

3. **Electromagnetic Interference (EMI) Sensitivity**

The flowmeter s performance can be affected by strong electromagnetic fields or nearby electrical equipment. Proper shielding and installation practices are required to avoid signal noise or measurement errors.

4. **Potential for Signal Drift Over Time**

While generally low-maintenance, the electrodes and lining (e.g., PTFE, rubber, or ceramic) may degrade over extended use, especially in highly corrosive or abrasive environments. This could require periodic inspection or replacement of components.

5. **Complex Installation Requirements**

The flowmeter requires proper upstream and downstream straight pipe runs (typically 5-10 pipe diameters) to ensure accurate measurements. Improper installation can lead to inaccurate readings or reduced lifespan.

6. **Limited Availability of Spare Parts**

Due to its specialized nature, finding replacement parts (e.g., electrodes, linings, or seals) may be challenging, particularly for older models. This could lead to extended downtime if maintenance is required.

7. **Not Ideal for Highly Viscous Fluids**

While the Promag can handle some viscous liquids, extremely high-viscosity fluids (e.g., heavy oils or slurries) may require additional considerations, such as larger pipe sizes or specific lining materials, to maintain accuracy.

8. **Potential for Lining Wear in Abrasive Media**

In applications involving abrasive slurries or solids, the internal lining may wear out faster, necessitating more frequent inspections or replacements. This adds to the long-term maintenance cost.

9. **Dependency on Proper Grounding**

Accurate operation requires proper grounding of the pipeline and flowmeter to avoid electrical interference. Poor grounding can lead to signal errors or equipment failure.

10. **Training and Expertise Required**

Due to its advanced features and calibration requirements, proper installation, configuration, and troubleshooting often demand specialized knowledge. Training for operators or maintenance personnel may be necessary, adding to the overall cost.

---

### **Conclusion**

The **Endress Hauser Promag 5H1B04-15J5/0 (5H1B22-2H41/0)** is a high-performance magnetic flowmeter ideal for applications requiring **precision, reliability, and durability** in conductive liquids. Its advanced features, such as digital communication, corrosion resistance, and low maintenance, make it a strong choice for industries like chemical processing, water treatment, and pharmaceuticals.

However, its **high cost, limited applicability to non-conductive fluids, and specific installation requirements** may not make it suitable for all applications. Businesses should carefully evaluate their budget, fluid properties, and operational needs before purchasing.

### **Recommendation**

- **Buy if:**

- You are working with **conductive liquids** (e.g., water, acids, slurries) in a **highly regulated or critical process**.

- You require **long-term reliability, minimal maintenance, and accurate flow measurement**.

- Your budget allows for a **premium, high-performance flowmeter** with advanced communication capabilities.

- Proper installation and grounding can be ensured to avoid signal issues.

- **Consider alternatives if:**

- Your application involves **non-conductive fluids** (e.g., gases, oils, or pure water), in which case **ultrasonic or turbine flowmeters** may be more appropriate.

- You are operating on a **tight budget** and can tolerate slightly lower accuracy or maintenance requirements.

- Your fluid is **extremely abrasive or viscous**, and you are concerned about lining wear.

- You lack the expertise for **proper installation, calibration, or troubleshooting**.

For most **industrial applications requiring precision and durability**, the Promag 5H1B series remains a **strong, long-term investment**. However, a thorough assessment of your specific needs including fluid type, budget, and operational environment will determine whether this flowmeter is the best fit.

Details:

5/32 low flow mag, scaled for 2gpm max. Guaranteed to work as new. 24VDC powered, pictures are of actual item being sold. Unit was used as a demo but never installed by customer.

Ethernet/IP PFA liner Included process connections are 1/2 PVC, but others readily available from E. Will pack VERY well for safe delivery.

part #: 5h1b0415j50 prices

  • $475.00-$1050.00

specifications pneumativalv:

  • brand: Endress Hauser
  • mpn: 5h1b04-15j5/0
  • flow meter type: Electromagnetic Flow Meter
  • port diameter: 5/32 In
  • maximum flow rate: 7.57 L/min
  • country of origin: France

returns pneumativalv:

  • policy: No Returns

offer pneumativalv:

  • sold: 0
  • started: March 30, 2026
  • availability: In Stock
  • best offers: True
  • quantity: 1
  • options: Ship-to-home

seller pneumativalv:

  • rating: 100.0%
  • # reviews: 736
  • city: San Ramon, California

payments pneumativalv:

  • other
  • credit card: Mastercard
  • wallet: Apple-pay

general pneumativalv:

  • Pump Flow Controllers > Flow Controllers Meters > Flow Meters
  • condition: Used

shipping pneumativalv:

  • cost: $29.30
  • carrier: FedEx
  • type: Calculated
  • service: FedEx Ground / FedEx Home Delivery
  • transit: 5-11 Days
  • class: Standard
flow meter type: electromagnetic flow meter, port diameter: 5/32 in, maximum flow rate: 7.57 l/min, country of origin: france,
category: business & industrial > pump flow controllers > flow controllers meters > flow meters, sku: 12052077469234752,
Endress Hauser 5H1B04-15J5-0 Is Similar To:
pneumativalv logo
2 offers $475.00–$1050.00 USD
  • Used. Offer #1 priced at $475.00 + $30.07 shipping estimate = $505.07* total. Will pack VERY well for safe delivery. Unit was used as a demo but never installed by customer.+$30.07 shipping
  • Used. Offer #2 priced at $1050.00 + $25.00 shipping estimate = $1075.00* total. The Endress + Hauser brand is known for producing durable and efficient flow meters, making this a trusted choice for businesses in need of accurate flow rate monitoring. The Endress + Hauser Promag H 100 Electromagnetic Flowmeter 5H1B08-3HH2/0 is a high-quality flow meter designed for accurate measurement of liquid and gas flow rates.+$25.00 shipping

Copyright © pneumativalv.com